Pressure Sensor
(addendum information)
(
)
Installation
Outline with Dimensions in mm
Attaching the connector to the lead wire
Connector
Connector Connecting Disconnecting
・When connecting the connector, insert it straight onto the pin
holding the lever and connector body between fingers and lock
the connector by pushing the lever claw into the square groove
in the housing until connector clicks.
・When disconnecting the connector, push down the lever by
thumb to disengage the lever claw from the square groove.
Then pull the connector straight out.
Operation Manual
PSE530 Series
PSE53 -M5
・Sensor wire is stripped as shown in
/
Connector
cover
M5 0.8
the right figure.
20mm or more
3.4
29.4
27.2
Pressure port
・The Insulation of the corresponding
color shown in the following table is
put into the pin of the number stamped
Insulation
on the connector for sensor connection to the bottom.
Pin No.
Color of Insulation
Brown (DC (+) )
N.C.
Blue (DC (-) )
Black (IN:1 to 5VDC)
3
12
1
2
3
4
4
5
5.5
PSE200 Series
PSE300 Series
PSE53 -R06
R07
A
1
2
3
4
・It checks that the above-mentioned preparation
work has been performed correctly, and A part
shown in right figure is pushed by hand and makes
temporary connection.
45.5
43.3
Pressure port
3.4
Lever
・A part center is straightly pushed in by tools, such as pliers.
・Re-use cannot be performed once it connects the connector for
sensor connection completely.
Connector for Sensor
Lead Wire
Lever
・A sensor connector cannot be taken apart for
reuse once it is crimped.If the wire arrangement
is incorrect or if the wire insertion fails,
Model No.
PSE53 -R06
PSE53 -R07
Applicable port size(D)
Thank you for purchasing the SMC PSE530 Series Pressure
Sensor.
Please read this manual carefully before operating pressure
sensor and understand pressure sensor, its capabilities and
limitations. Please keep this manual handy for future reference.
6mm
Example of Internal Circuit and Wiring
Output Specification
1/4inch
4
3
2
use a new sensor connector.
1
・When connecting the connector to
PSE200/PSE300 series, please use
When connect cable for sensor
Brown DC
(+)
Voltage output :
1 to 5V
Output impedance :
9.8
the connector for Sensor Lead Wire(ZS-28-C) or
as below.
Model No.
37104-3101-000FL
1k
Ω
Maker
(c)Sumitomo 3M
Tyco Electronics AMP
OMRON
Black OUT
(Analog output)
Approx. 1kΩ
+
-
12 to 24V
DC
3-1473562-4
XN2A-1430
Blue DC
(-)
・
Please contact with each connector maker about
catalogue.
SAFETY
Specification
The Pressure Sensor and this manual contain essential
information for the protection of users and others from possible
injury and property damage and to ensure correct handling.
Please check that you fully understand the definition of the
following messages (signs) before going on to read the text,
and always follow the instructions.
How to connect the cable for sensor.(Optional)
Pick with fingers the hemale connector of cable for sensor.
Insert it paying attention of connector direction.
OPERATOR
※
※
※
※
PSE533-
Model No.
PSE530-
PSE531-
PSE532-
●This operation manual has been written for those who have
knowledge of machinery and apparatus that use pneumatic
equipment and have full knowledge of assembly, operation
and maintenance of such equipment.
Rated pressure range 0 to 101MPa 0 to -101kPa 0 to 101kPa -101 to 101kPa
Withstand pressure
Fluid
1.5MPa
500kPa
Air, Non-corrosive gases, Incombustible gases
12 to 24VDC, ripple(p-p)10% or less (Protection against inverse connection)
15mA or less
Power supply
Current consumption
●Please read this operation manual carefully and understand it
before assembling, operating or providing maintenance
service to the pressure sensor.
Sensor
IMPORTANT MESSAGES
Read this manual and follow its instructions. Signal words
such as WARNING and NOTE will be followed by important
safety information that must be carefully reviewed.
Voltage: 1 to 5V±2%F.S. or less (Rated pressure range)
Linearity : ±1%F.S. or less Output impedance : Approx.1kΩ
Analog
output
Voltage
output
Male connector
Repeatability
±1%F.S. or less
NOTE
Effect form power supply
Temperature Characteristic
Enclosure
±1%F.S. or less with standard of analog output at 18V in the range of 12 to 24VDC
±2%F.S. or less (25℃ reference)
Female connector
Indicates a potentially hazardous situation
which could result in death or serious
injury if you do not follow instructions.
Follow the instructions given below when handling your
pressure sensor. Otherwise, the sensor may be damaged
or may fail, thereby resulting in malfunction.
IP40
Cable for sensor have connector cover in order to prevent fall of
female connector. Paying attention for connector cover direction,
install on the sensor, rotate clockwise, and lock it.
To remove cable for sensor, rotate the connector cover anti-
clockwise, relese lock, and remove connector cover.
After removing connector cover, pick with female connector with
fingers and pull out.
Operation : 0 to 50℃,Storage :-10 to 70℃ (No condensation, No freezing)
1000VAC, 50/60Hz, 1minute (Between lead block and case)
5MΩ or more 500VDC (Between lead block and case)
Ambiebt temperature
Withstand voltage
Insulation resistance
・Do not drop it, bring it into collision with other objects or apply
excessive shock (980m/s2 or more).
・Do not pull the lead wire with force nor lift the main unit by
holding the lead wire. (Pulling strength less than 23N)
・Do not insert wire nor other article into the pressure port.
・Perform wiring and cable correctly.
・Do not perform wire or cable while power is on.
・Do not wire with the same circuit of power line or high-voltage
line.
・Connect Terminal FG to the ground when using a switching
regulator obtained on the commercial market.
・Keeping from water and dust, set an air tube to the safety
area.
WARNING
10 to 500Hz smaller one 1.5mm or 98m/s2 double amplitude, 2 hours each in direction
of X, Y and Z
Vibration proof
Do not disassemble, remodel (including change of
printed circuit board) or repair.
An injury or failure can result.
980m/s2 3times each in directions of X ,Y and Z respectively
CE MARKING
Impact proof
Standard
Halogen free heavy insulation cable, φ2.7, 0.15mm2, 3wire, 3m
Cable
Lock
Do not operate beyond specification range.
Fire, malfunction or sensor damage can result.
Piping Specification
Model No.
Sensor
M5
R06
R07
Connector cover
Port size
M5×0.8
φ6 Reducer
1/4inch Reducer
Do not operate in a combustible gas or explosive
gas atmosphere.
Fire or an explosion can result.
Sensor pressure sensing part : Silicon O-ring : NBR
Material
Unlock
Body : SUS303
Body : PBT
38g
41g
7g
With cable(3m)
Weight
This pressure sensor is not an explosion proof type.
3.8g
Excluding cable
|